An alarm nobody believes is not an alarm

An alarm is only worth something if it sounds when something is wrong, and only then. Too early and it is ignored, too late and it is useless. Where it is set is the whole question.

Reading Time: 5 minutes

An alarm is only worth something if it sounds when something is wrong, and only then. Set too early, it sounds every day and people stop looking. Set too late, it never warns anyone. Where it is set is the whole question.

Two ways to fail

Every alarm is a promise to the person on watch: if this sounds, something needs your attention now. The promise holds only inside a narrow band. The alarm has to sit beyond normal operation, so that it stays quiet while things are going to plan. And it has to sit early enough that someone can still act.

Move it out of that band in either direction and it stops being a safeguard. A ship can have alarms at both ends.

The alarm that sounds all the time

Lloyd’s Register published a study in 2024 based on 65 watchkeepers from 15 ships run by 10 companies. LR calls it an initial exploration, and its numbers should be read that way. In LR’s two bridge recordings on sister passenger ships, the average alarm rate was 9.5 an hour in open sea, 18.3 in coastal waters and 27.9 in confined waters. On one ship’s bridge, passing the Strait of Gibraltar at night, it reached 74 an hour. More than 60% of the bridge officers surveyed said that 40% or more of their alarms were repeats of one they had seen in the last five minutes. LR’s 2026 follow-up, covering more than 40 million alarm events on 11 vessels, found that fewer than half of them met the recommended benchmark of fewer than 30 alarms an hour.

IMO’s Code on Alerts and Indicators (A.1021(26)) already says the aim, in paragraph 4.17: “Means should be provided to prevent normal operating conditions from causing false alerts.” A study cannot say how many alarms on a given ship are set wrongly. But the effect of a crowded alarm list is in the investigation reports LR cites.

On Viking Sky, LR reports, citing the Norwegian investigators’ preliminary findings, that the crew had accepted and cleared 18 alarms on low lubrication oil levels in four hours that morning, before the blackout. The final report counts them differently: four low lubricating oil level alarms on one generator’s sump tank, acknowledged with no further action, among about 200 alarms over two watches, 88 of them tank level warnings probably caused by a faulty signal. Either way, the warnings were accepted and nothing was done. Hours later the low oil pressure shutdowns came, the ship lost propulsion, and she is estimated to have come within a ship’s length of running aground.

The error runs the other way too. An alarm that is wrong can do harm through the shutdown it triggers. LR cites a false oil mist alarm that stopped a main engine and led to a collision, and a false oil pressure alarm that cost a container ship 260 containers in heavy weather.

The alarm that has already sounded, or comes too late

Take a cargo tank loaded to its limit of 98%, leaving 2% for expansion, with the valve shut while the ship goes on loading other tanks. ISGOTT tells the ship to check the ullages of topped-off tanks from time to time, because a leaking valve or a wrong line-up can keep cargo flowing into a tank everyone believes is closed. Suppose that happens.

If the high-level alarm sits at 98%, it sounded when the tank reached its limit and was acknowledged. It is already in alarm, and a leak that follows tells nobody anything new. An alarm at 95% is worse. It sounds on every normal loading and has long since become routine.

Place the alarm just beyond the loading limit and it stays silent through normal loading. It sounds only when cargo is coming into a tank that should be shut. That is what makes it useful. It is the backstop, and the ullage check is still the primary defence.

But the margin works against you. Every point beyond the limit is volume lost, and the alarm must still leave time to stop the flow, whether the cause is a slow leak or a valve in the wrong position. How far beyond is settled long before the ship sails, by the designer, the rules the ship is built to and then the company procedure. That is why the person on watch needs to know the reasoning. An alarm they do not understand is one they cannot trust.

The same dial exists across the bridge. An ECDIS safety contour is set from the ship’s draught and the clearance she needs. Set deeper than the water actually requires, it sounds through the whole approach. Set shallower, the warning arrives when there is little water left. A CPA limit wide enough to catch every fishing boat will be silenced. One too narrow gives no time to alter. In both cases the alarm exists, and it is tested and works. It simply no longer says what the watchkeeper needs it to say.

Who decides, and why

Most set points are made long before the watchkeeper meets them. In some installations the set point is fixed by where the sensor is mounted, a decision taken at the yard. Others come from the rules the ship is built to and from the company procedure. A few are set on board, such as the ECDIS safety contour.

LR makes a separate point. None of the policymakers, such as the IMO, flag States or classification societies, imposes a process to minimise the number of alarms or sets objective criteria such as an allowable response time or a maximum alarm rate for each watchkeeper, so adding another alarm remains the easy fix. Among the signs LR found in organisations that managed alarms well was the continuous removal of stale alarms from the list screen.

Questions to ask of any alarm

  1. What does it protect against, and who acts when it sounds?
  2. Where is it set, and who decided?
  3. Does it sound during normal operation? If it does, why?
  4. If it sounds, is there still time to do something about it?
  5. When was it last tested, and what happened when it was?

If the honest answer to the third question is “yes, all the time”, the alarm has already stopped working, whatever the test records say. If the answer to the fourth is “no”, it was never going to.

Where an alarm fails these questions, the fix is rarely a silenced alarm. It is a report to the office, so that whoever owns the set point can look at it.

An alarm that nobody believes is the same problem as a procedure that nobody follows, which I looked at in When the whole fleet skips the step, the procedure is the finding. And whether a watchkeeper says so when an alarm seems wrong is a question of trust, covered in the VDR and bridge team trust piece. Alarms that keep going off also cost people their sleep, which I looked at in The rest hours are perfect. The crew is not.

Each alarm on a ship was added by someone for a reason. The test is whether anyone on watch still believes it.

Sources: Lloyd’s Register, “Effective Alarm Management in the Maritime Industry” (2024), including incident findings it cites from the Norwegian Safety Investigation Authority and the US National Transportation Safety Board, and its 2026 follow-up; Norwegian Safety Investigation Authority, Report MARINE 2024/05, Loss of propulsion and near grounding of Viking Sky; IMO Resolution A.1021(26), Code on Alerts and Indicators, 2009; ISGOTT, 6th edition, section 12.1.6.14.

Disclosure: this site uses AI tools to help with research and drafting. The views in this article are the author’s. It is general commentary and not professional advice.

Written by
Capt. Gaurav Khanna

Capt. Gaurav Khanna is a Master Mariner, the founder of VragaMarine and the editor of Maritime Dossier. He spent 18 years at sea on product tankers and crude carriers, trading the Persian Gulf, the North Sea and the Baltic, before coming ashore in 2013. He then spent 13 years ashore with a Japanese ship management company, rising to Senior Deputy General Manager…

Views expressed are the author's own and do not represent those of their employer.

LinkedIn profile
Follow Maritime Dossier on LinkedIn to see new entries as they are published.Follow

Leave a Reply

Your email address will not be published. Required fields are marked *